SEWTECHSupport Center 简体中文

Replace a Needle on the ST-1501

Applies to ST-1501

Watch on YouTube ↗

Overview

Replace a broken needle on the SEWTECH ST-1501. The guide shows how to loosen the screw just enough, remove the broken needle, face the new needle’s long groove forward, push the shank all the way up and secure the needle.

Step-by-step guide

1. Get the tools and replacement needle ready

Watch at 00:08

Bring the ST-1501 to a complete stop before working at the needle head. Have a small flat-blade screwdriver, needle-nose pliers and a replacement needle for the ST-1501 ready. The screwdriver is for the retaining screw. The pliers are for removing the broken needle and holding the replacement.

Set aside a small flat-blade screwdriver for the screw in the needle holder.
Set aside a small flat-blade screwdriver for the screw in the needle holder.
The narrow jaws of the pliers can reach the needle below the holder.
The narrow jaws of the pliers can reach the needle below the holder.

2. Slightly loosen the needle-retaining screw

Watch at 00:16

From the front of the head, follow the damaged needle up to its holder. Fit the flat blade into the small slotted screw at that needle position. Turn gently just enough to release the needle, leaving the screw in the holder.

The screwdriver tip locates the small retaining screw at the right-hand needle position shown in the video.
The screwdriver tip locates the small retaining screw at the right-hand needle position shown in the video.
After the screwdriver is withdrawn, the retaining screw is still in the holder.
After the screwdriver is withdrawn, the retaining screw is still in the holder.

3. Remove the broken needle with pliers

Watch at 00:30

Grip the exposed part of the broken needle just below the loosened holder. Withdraw it carefully downward while keeping hold of it with the pliers. Once the remaining needle is clear of the holder, use that same opening for the replacement.

The jaws grip the needle immediately below the loosened holder.
The jaws grip the needle immediately below the loosened holder.
The pliers lower the broken needle out of the holder.
The pliers lower the broken needle out of the holder.

4. Face the long groove toward the front

Watch at 00:44

Hold the new needle with the point down. Find the long groove running along the blade toward the eye. When you are facing the machine, that groove should face you. Keep this orientation when you lift the needle into place.

The demonstrator points to the groove side while holding the replacement needle against her palm.
The demonstrator points to the groove side while holding the replacement needle against her palm.
The source video inset enlarges the side of the needle with the long groove. This is the face that points forward.
The source video inset enlarges the side of the needle with the long groove. This is the face that points forward.

5. Guide the shank into the holder from below

Watch at 00:55

Bring the new needle to the same position with the shank up and the point down. Line up the shank with the opening on the underside of the holder and guide it upward by hand, keeping the groove toward the front.

Hold the replacement upright with its thicker shank uppermost.
Hold the replacement upright with its thicker shank uppermost.
Start the shank in the opening beneath the same needle holder.
Start the shank in the opening beneath the same needle holder.

6. Push the needle fully up to the stop

Watch at 01:02

Hold the needle steady with the needle-nose pliers as shown. Push it straight up until it stops against the top inside the holder. Keep the needle supported there while you prepare to check its position.

Bring the pliers up to the needle after starting the shank by hand.
Bring the pliers up to the needle after starting the shank by hand.
The pliers guide the needle straight upward to the stop inside the holder.
The pliers guide the needle straight upward to the stop inside the holder.

7. Recheck the seating and groove

Watch at 01:15

Before tightening, check that the needle is still fully up against the stop and that the long groove still faces forward. If the needle has slipped down or turned, reseat it with the groove facing you before tightening the screw.

The pliers continue supporting the needle while the screwdriver is held away for the final position check.
The pliers continue supporting the needle while the screwdriver is held away for the final position check.
Check that the needle has stayed up in the holder before bringing the driver back to the screw.
Check that the needle has stayed up in the holder before bringing the driver back to the screw.

8. Tighten the same retaining screw

Watch at 01:28

Keep the needle steady with the pliers so it stays seated and facing forward. Return the flat-blade screwdriver to the same screw and tighten it securely. Once the screw is tight, withdraw the screwdriver and pliers.

The screwdriver returns to the same screw while the pliers hold the needle below it.
The screwdriver returns to the same screw while the pliers hold the needle below it.
Keep the needle supported as you finish tightening the screw.
Keep the needle supported as you finish tightening the screw.

9. Confirm the needle stays in place

Watch at 01:36

With the tools clear, confirm that the replacement remains straight and seated in the holder, with the long groove facing the front. The video ends with the needle head stationary after this visual check.

With both tools removed, the replacement needle remains in the right-hand holder shown in the demonstration.
With both tools removed, the replacement needle remains in the right-hand holder shown in the demonstration.
The final front view shows the stationary needle row after installation.
The final front view shows the stationary needle row after installation.