SEWTECHSupport Center 简体中文

Replace a Needle on the ST-1201 and SC-1501

Applies to ST-1201 / SC-1501 Demonstrated on ST-1201

Watch on YouTube ↗

Overview

Stop the machine before working at the needle bar. Have a flat-blade screwdriver from the toolbox, needle-nose pliers and a compatible replacement needle ready. The demonstration uses the ST-1201 and shows how to check the needle mechanically before returning the machine to service.

Step-by-step guide

1. Loosen the needle clamp screw

Watch at 00:14

At the bottom of the machine head, locate the small slotted screw above the presser foot for the needle you are replacing. Set the flat blade into the slot and turn it slowly, just enough to release the needle. Leave the screw in the clamp.

Use the flat-blade screwdriver from the toolbox.
Use the flat-blade screwdriver from the toolbox.
The blade meets the small clamp screw at the rightmost needle position in the demonstration.
The blade meets the small clamp screw at the rightmost needle position in the demonstration.
Withdraw the screwdriver and leave the loosened screw in place.
Withdraw the screwdriver and leave the loosened screw in place.

2. Remove the broken needle

Watch at 00:28

Bring the needle-nose pliers in beside the presser foot. Grip the exposed portion of the broken needle below the clamp and gently pull it down and clear. The removed needle should come away with the pliers.

Use the narrow jaws of the pliers to reach the needle position.
Use the narrow jaws of the pliers to reach the needle position.
Grip the exposed needle beside the presser foot.
Grip the exposed needle beside the presser foot.
The removed needle is visible in the pliers, clear of the machine head.
The removed needle is visible in the pliers, clear of the machine head.

3. Face the long groove toward you

Watch at 00:38

Take out the replacement needle and hold it upright with the point down. Find the long groove running down the needle toward its eye and turn that groove toward you, facing the front of the machine. Keep this orientation as you insert the needle. The pack shown is marked DB × K5, Nm 75/11.

The needle pack in this demonstration is marked DB × K5, Nm 75/11.
The needle pack in this demonstration is marked DB × K5, Nm 75/11.
The inset shows the long groove that must face you.
The inset shows the long groove that must face you.

4. Guide the new needle through the presser foot

Watch at 00:53

Bring the new needle straight up from below the presser foot, with the thicker shank leading. Pass the shank through the opening in the foot at the same needle position, then take hold of the needle with the pliers. Keep the long groove facing forward as you bring the shank toward the holder above.

Bring the needle shank up under the presser-foot opening.
Bring the needle shank up under the presser-foot opening.
The needle is upright through the opening in the foot.
The needle is upright through the opening in the foot.
Take hold of the needle with the pliers while keeping it aligned.
Take hold of the needle with the pliers while keeping it aligned.

5. Seat the needle against the top of the holder

Watch at 00:59

Guide the shank into the needle holder directly above the presser foot. Use the pliers to push the needle straight up until it stops at the top of the holder. Before tightening, check that it has reached that stop and that the long groove still faces forward.

The pliers guide the shank upwards into the holder above the foot.
The pliers guide the shank upwards into the holder above the foot.
Keep the needle supported as you check that it has reached the upper stop.
Keep the needle supported as you check that it has reached the upper stop.

6. Hold the needle up and tighten the screw

Watch at 01:14

Keep the needle fully seated with the pliers while you bring the flat-blade screwdriver back to the same clamp screw. Tighten the screw firmly. Once the screw holds the needle, release the pliers and remove both tools.

The pliers keep the needle up while the screwdriver returns to the clamp screw.
The pliers keep the needle up while the screwdriver returns to the clamp screw.
Tighten the screw while the pliers still support the needle.
Tighten the screw while the pliers still support the needle.
The tools move away after the clamp holds the needle.
The tools move away after the clamp holds the needle.

7. Check that the installed needle stays in place

Watch at 01:19

With both tools clear, confirm the needle remains upright at its needle position, fully seated and secure, with the long groove facing you. The video ends the procedure with this close-up of the stationary needle row.

The final close-up shows the needle row and clamp screws after the tools have been removed.